From low tension through medium to high tension (up to 800 kV) we have earthing and short-circuiting equipment and devices manufactured from the highest quality materials with more than 60 years of experience and knowledge.
All our own products can be personalized for your requirments and needs.
Priority is SAFETY FIRST.
![cable-current-danger-236089 cable-current-danger-236089](https://krohn.dk/lkh/wp-content/uploads/bb-plugin/cache/cable-current-danger-236089-1024x683-panorama.jpg)
![wm wm](https://krohn.dk/lkh/wp-content/uploads/bb-plugin/cache/wm-1024x583-panorama.jpg)
1 / EARTHING DEVICES
1- and 3-phase earthing devices for indoor and outdoor switchgears, overhead lines, substations
All the equipment has undergone extremely stringent type tests and is tested and approved according to current standards.
A complete set of earthing equipment consists of:
- Earthing devices (Line clamp, Earth clamp, Earthing cable),
- Contact fitting
- Operating pole and operating socket
By providing the necessary technical specifications details we design and manufacture the safest and the most reliable earthing device.
![jk42-jla34___norm jk42-jla34___norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk42-jla34___norm.png)
![jk23-jk23v1_norm jk23-jk23v1_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk23-jk23v1_norm-1.png)
![jk23kp-x1-jk23h jk23kp-x1-jk23h](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk23kp-x1-jk23h.jpg)
![jsk-jla30 jsk-jla30](http://krohn.dk/lkh/wp-content/uploads/2018/10/jsk-jla30.jpg)
2 - LINE / EARTH CLAMPS
![jk27 jk27](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk27.jpg)
![jk23h4 jk23h4](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk23h4.jpg)
![jk42_norm jk42_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk42_norm.png)
![jk81_norm jk81_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk81_norm.png)
![jk238 jk238](http://krohn.dk/lkh/wp-content/uploads/2018/10/jk238.jpg)
![jfs17_norm jfs17_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jfs17_norm.png)
3 - CONTACT FITTINGS
There is a wide range of contact fittings for application to tubes, bars, lines, frames etc
They are made for connection to conductors or to earth.
The conducting parts of the contact fittings are made of high-quality material like aluminium bronze, aluminium, copper and brass. The contact fittings are hardened and/or surface treated where appropriate. Stainless steel is mainly used for the other parts. Peak current factor is 2,5 x Ir (rated current), unless otherwise stated.
![rs_1020a1 rs_1020a1](http://krohn.dk/lkh/wp-content/uploads/2018/10/rs_1020a1.jpg)
![rs10202 rs10202](http://krohn.dk/lkh/wp-content/uploads/2018/10/rs10202.jpg)
![jkr_10_b1 jkr_10_b1](http://krohn.dk/lkh/wp-content/uploads/2018/10/jkr_10_b1.jpg)
![jkr_10_a1 jkr_10_a1](http://krohn.dk/lkh/wp-content/uploads/2018/10/jkr_10_a1.jpg)
![jkc_3_norm jkc_3_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jkc_3_norm.png)
![jka_2890_norm jka_2890_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/jka_2890_norm.png)
![jvf_11 jvf_11](http://krohn.dk/lkh/wp-content/uploads/2018/10/jvf_11.jpg)
![jvf_37 jvf_37](http://krohn.dk/lkh/wp-content/uploads/2018/10/jvf_37.jpg)
4 - INSULATED POLES
EN 61230, EN 61235, EN 61243-1, SS 428 91 10,
Insulating poles are available in fixed-, jointed- or telescopic design.
The insulating poles are made of glass fibre reinforced vinyl ester. This material has a very good electrical insulating quality and at the same time the relation between weight-strength and stiffness is excellent. A special method of manufacturing, which makes the surface plain, eliminates the risk of the glass fibre particles coming out of the pole, which otherwise may be inconvenient at use.
The poles are coloured throughout and do not need to be varnished.
The range includes operating poles, branch cutting poles, snow removal poles, measuring poles and cases.
![mgv-u1_norm mgv-u1_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/mgv-u1_norm.png)
![mtv150-k_norm mtv150-k_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/mtv150-k_norm.png)
![mgv_vtu_norm mgv_vtu_norm](http://krohn.dk/lkh/wp-content/uploads/2018/10/mgv_vtu_norm.png)
![mst_9_5 mst_9_5](http://krohn.dk/lkh/wp-content/uploads/2018/10/mst_9_5.jpg)
![mrk-u_36 mrk-u_36](http://krohn.dk/lkh/wp-content/uploads/2018/10/mrk-u_36.jpg)